STUDI PERENCANAAN PONDASI RAKIT (RAFT FOUNDATION) PADA GEDUNG KATERING 5 LANTAI DI PONDOK PESANTREN KEDUNGLO KEDIRI
Kata Kunci:
Pondasi Rakit, Daya Dukung Tanah, SAP2000, Gedung Katering, Tekanan Kontak TanahAbstrak
Abstrak
Gedung Katering 5 lantai di Pondok Pesantren Kedunglo, Kediri direncanakan berdiri di atas lahan yang padat bangunan dengan akses terbatas, sehingga penerapan pondasi dalam seperti tiang pancang menghadapi kendala mobilisasi alat berat, getaran, dan kebisingan terhadap permukiman sekitar. Kondisi tanah di lokasi didominasi lempung lunak hasil endapan aluvial dengan daya dukung relatif rendah, sehingga pondasi rakit (raft foundation) dipilih sebagai alternatif karena mampu mendistribusikan beban secara merata pada pelat beton berdimensi luas. Penelitian ini bertujuan menghitung beban rencana struktur atas, menentukan dimensi dan penulangan pondasi rakit, serta mengevaluasi kriteria keamanan geoteknik dan struktural sesuai SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, dan SNI 8460:2017. Data tanah diperoleh dari uji sondir (CPT) lima titik oleh PT. Sarana Data Persada, dengan tegangan izin tanah (qall) desain sebesar 4,75 t/m². Analisis struktur atas menggunakan SAP2000 menghasilkan total beban ΣP sebesar 7.680,52 ton. Dimensi awal pondasi rakit ditetapkan 31 m x 13 m dengan tebal 800 mm. Kontrol tekanan kontak tanah menunjukkan q sebesar 10,60 t/m², melampaui qall 4,75 t/m² sehingga dimensi awal belum memenuhi syarat daya dukung dan memerlukan perbesaran dimensi atau perbaikan tanah pada tahap perencanaan lanjutan. Hasil pemodelan pelat pondasi memperlihatkan momen tumpuan maksimum arah X sebesar 1170,51 kNm/m dan arah Y sebesar 1023,14 kNm/m yang menjadi dasar perhitungan penulangan lentur pondasi.
Abstract
The 5-story Catering Building at Pondok Pesantren Kedunglo, Kediri, is planned on a densely built site with limited access, making deep foundations such as driven piles impractical due to heavy-equipment mobilization, vibration, and noise affecting the surrounding settlement. The site is dominated by soft alluvial clay with relatively low bearing capacity, so a raft foundation was selected as it distributes the building load evenly through a large concrete slab. This study calculates the superstructure design loads, determines the raft foundation dimension and reinforcement, and evaluates geotechnical and structural safety criteria referring to SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, and SNI 8460:2017. Soil data were obtained from five-point Cone Penetration Tests (CPT) by PT. Sarana Data Persada, with a design allowable soil pressure (qall) of 4.75 t/m². Superstructure analysis using SAP2000 resulted in a total load (ΣP) of 7,680.52 tons. The initial raft dimension was set at 31 m x 13 m with an 800 mm thickness. The soil contact pressure check produced q of 10.60 t/m², exceeding the qall of 4.75 t/m², indicating that the initial dimension does not yet satisfy the bearing capacity requirement and requires dimension enlargement or ground improvement in further design. The slab modeling results show a maximum support moment of 1170.51 kNm/m in the X-direction and 1023.14 kNm/m in the Y-direction, used as the basis for flexural reinforcement design.
Unduhan
Unduhan
Diterbitkan
Terbitan
Bagian
Lisensi
Hak Cipta (c) 2026 KEDUNG KARYA

Artikel ini berlisensiCreative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.